{ "$schema": "https://schemas.kicad.org/drc.v1.json", "coordinate_units": "mm", "date": "2026-09-20T22:39:18", "ignored_checks": [ { "description": "Footprint has no courtyard defined", "key": "missing_courtyard" }, { "description": "Track endpoint not centered on via", "key": "track_not_centered_on_via" }, { "description": "Tuning profile track geometries", "key": "tuning_profile_track_geometries" }, { "description": "Footprint doesn't match symbol's footprint filters", "key": "footprint_filters_mismatch" }, { "description": "Footprint component type doesn't match footprint pads", "key": "footprint_type_mismatch" } ], "included_severities": [ "error", "warning" ], "kicad_version": "10.0.6", "schematic_parity": [], "source": "serial-carrier.kicad_pcb", "unconnected_items": [ { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 19 [/BTN_SELECT] von U1", "pos": { "x": 108.0, "y": 149.72 }, "uuid": "f7b9badd-1db5-4575-9da8-979a7c8f3946" }, { "description": "Durchsteckpad 1 [/BTN_SELECT] von SW2", "pos": { "x": 155.0, "y": 168.0 }, "uuid": "574d93e4-d3fc-4c28-b2d5-4e7d8682c22f" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/BTN_SELECT] von SW2", "pos": { "x": 155.0, "y": 168.0 }, "uuid": "574d93e4-d3fc-4c28-b2d5-4e7d8682c22f" }, { "description": "Durchsteckpad 1 [/BTN_SELECT] von SW2", "pos": { "x": 161.5, "y": 168.0 }, "uuid": "0398530b-79dc-45b1-886c-51343182e1d3" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/BTN_SELECT] von SW2", "pos": { "x": 161.5, "y": 168.0 }, "uuid": "0398530b-79dc-45b1-886c-51343182e1d3" }, { "description": "Durchsteckpad 2 [/BTN_SELECT] von R2", "pos": { "x": 161.62, "y": 134.0 }, "uuid": "c118f27f-8ad4-4abe-b9c0-a30a22fe60c9" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 22 [/GND] von U1", "pos": { "x": 108.0, "y": 157.34 }, "uuid": "9d509ec2-7588-4c77-9146-8d03c8646e37" }, { "description": "Durchsteckpad 44 [/GND] von U1", "pos": { "x": 133.4, "y": 157.34 }, "uuid": "91b9e8e9-7e2c-43ab-b2ef-ec8ba16a25f1" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 23 [/GND] von U1", "pos": { "x": 133.4, "y": 104.0 }, "uuid": "b66490f6-5d60-415d-babb-215c70511b77" }, { "description": "Durchsteckpad 2 [/GND] von U2", "pos": { "x": 145.54, "y": 130.0 }, "uuid": "7744910d-b37b-4fd5-a46a-95ee262d2a08" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 43 [/GND] von U1", "pos": { "x": 133.4, "y": 154.8 }, "uuid": "23b353d7-7ede-43a0-a655-57496d4f8aee" }, { "description": "Durchsteckpad 1 [/GND] von DS1", "pos": { "x": 152.19, "y": 137.5 }, "uuid": "0d95ad6d-f278-4240-9618-08ad8fcb5e1c" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 44 [/GND] von U1", "pos": { "x": 133.4, "y": 157.34 }, "uuid": "91b9e8e9-7e2c-43ab-b2ef-ec8ba16a25f1" }, { "description": "Durchsteckpad 43 [/GND] von U1", "pos": { "x": 133.4, "y": 154.8 }, "uuid": "23b353d7-7ede-43a0-a655-57496d4f8aee" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/GND] von SW1", "pos": { "x": 143.0, "y": 172.5 }, "uuid": "cc9a376c-9410-4f75-a7a6-3a849cc384b3" }, { "description": "Durchsteckpad 2 [/GND] von SW1", "pos": { "x": 149.5, "y": 172.5 }, "uuid": "24c82a41-4f9f-4c94-aaaf-2a3df71bbd08" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/GND] von SW1", "pos": { "x": 143.0, "y": 172.5 }, "uuid": "cc9a376c-9410-4f75-a7a6-3a849cc384b3" }, { "description": "Durchsteckpad 44 [/GND] von U1", "pos": { "x": 133.4, "y": 157.34 }, "uuid": "91b9e8e9-7e2c-43ab-b2ef-ec8ba16a25f1" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/GND] von SW1", "pos": { "x": 149.5, "y": 172.5 }, "uuid": "24c82a41-4f9f-4c94-aaaf-2a3df71bbd08" }, { "description": "Durchsteckpad 2 [/GND] von SW2", "pos": { "x": 155.0, "y": 172.5 }, "uuid": "970e56ae-cc93-46cd-8807-ccc9cf082aa1" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/GND] von DS1", "pos": { "x": 152.19, "y": 137.5 }, "uuid": "0d95ad6d-f278-4240-9618-08ad8fcb5e1c" }, { "description": "Durchsteckpad 2 [/GND] von U2", "pos": { "x": 145.54, "y": 130.0 }, "uuid": "7744910d-b37b-4fd5-a46a-95ee262d2a08" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/GND] von SW2", "pos": { "x": 155.0, "y": 172.5 }, "uuid": "970e56ae-cc93-46cd-8807-ccc9cf082aa1" }, { "description": "Durchsteckpad 2 [/GND] von SW2", "pos": { "x": 161.5, "y": 172.5 }, "uuid": "2f44f580-c7e4-4f03-ba46-49605735875c" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/GND] von SW2", "pos": { "x": 161.5, "y": 172.5 }, "uuid": "2f44f580-c7e4-4f03-ba46-49605735875c" }, { "description": "Durchsteckpad 2 [/GND] von SW3", "pos": { "x": 167.0, "y": 172.5 }, "uuid": "3cdbd911-6e07-4f86-8887-5953fa3d2a01" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/GND] von SW3", "pos": { "x": 167.0, "y": 172.5 }, "uuid": "3cdbd911-6e07-4f86-8887-5953fa3d2a01" }, { "description": "Durchsteckpad 2 [/GND] von SW3", "pos": { "x": 173.5, "y": 172.5 }, "uuid": "8e780381-cbfb-4f62-ae3b-8b0b8fa2a6a8" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/+3V3] von U1", "pos": { "x": 108.0, "y": 104.0 }, "uuid": "9aaad355-039f-439b-9cd7-308d07ace02e" }, { "description": "Durchsteckpad 2 [/+3V3] von U1", "pos": { "x": 108.0, "y": 106.54 }, "uuid": "2c8cc7c5-7b73-4bc2-a384-b3a5ac459c92" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/+3V3] von U2", "pos": { "x": 143.0, "y": 130.0 }, "uuid": "f8aafd85-e635-47cd-ba22-ddf4a036d1cd" }, { "description": "Durchsteckpad 1 [/+3V3] von R1", "pos": { "x": 143.0, "y": 134.0 }, "uuid": "56ff90bc-b894-4f81-8274-7a34384229e7" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/+3V3] von U2", "pos": { "x": 143.0, "y": 130.0 }, "uuid": "f8aafd85-e635-47cd-ba22-ddf4a036d1cd" }, { "description": "Durchsteckpad 2 [/+3V3] von U1", "pos": { "x": 108.0, "y": 106.54 }, "uuid": "2c8cc7c5-7b73-4bc2-a384-b3a5ac459c92" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/+3V3] von R2", "pos": { "x": 154.0, "y": 134.0 }, "uuid": "73a249ed-c3b1-46fb-afd5-f8bfe0e3fa65" }, { "description": "Durchsteckpad 1 [/+3V3] von R1", "pos": { "x": 143.0, "y": 134.0 }, "uuid": "56ff90bc-b894-4f81-8274-7a34384229e7" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/+3V3] von DS1", "pos": { "x": 154.73, "y": 137.5 }, "uuid": "62a98206-7a36-4b20-a201-d4ca10b404df" }, { "description": "Durchsteckpad 1 [/+3V3] von R2", "pos": { "x": 154.0, "y": 134.0 }, "uuid": "73a249ed-c3b1-46fb-afd5-f8bfe0e3fa65" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/+3V3] von DS1", "pos": { "x": 154.73, "y": 137.5 }, "uuid": "62a98206-7a36-4b20-a201-d4ca10b404df" }, { "description": "Durchsteckpad 1 [/+3V3] von R3", "pos": { "x": 165.0, "y": 134.0 }, "uuid": "72b8a1ea-1fa7-480b-8122-aceb08f4bb4b" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 4 [/RS_DCD] von U1", "pos": { "x": 108.0, "y": 111.62 }, "uuid": "d9f0d2af-a701-43e9-9d1e-58a6c7cb5250" }, { "description": "Durchsteckpad 3 [/RS_DCD] von U2", "pos": { "x": 148.08, "y": 130.0 }, "uuid": "d589a6a4-0d53-4c2a-8f68-fb4407d9f10e" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 5 [/RS_DSR] von U1", "pos": { "x": 108.0, "y": 114.16 }, "uuid": "0ceca603-53a8-4a53-85cc-f7f8e7be90e4" }, { "description": "Durchsteckpad 7 [/RS_DSR] von U2", "pos": { "x": 158.24, "y": 130.0 }, "uuid": "e2d6b2cb-6025-490c-8371-d7cc34ac37f6" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 6 [/RS_RI] von U1", "pos": { "x": 108.0, "y": 116.7 }, "uuid": "f35f1696-b778-437b-8cce-67b8c4d5f5d0" }, { "description": "Durchsteckpad 10 [/RS_RI] von U2", "pos": { "x": 165.86, "y": 130.0 }, "uuid": "e28de6f2-fb85-4849-ba1a-e98e2a231492" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 7 [/RS_DTR] von U1", "pos": { "x": 108.0, "y": 119.24 }, "uuid": "354ab122-85b1-4c9c-9385-d5091fe12303" }, { "description": "Durchsteckpad 6 [/RS_DTR] von U2", "pos": { "x": 155.7, "y": 130.0 }, "uuid": "81e8ad67-4bdc-4f57-90b1-68cff6a95261" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 8 [/RS_RTS] von U1", "pos": { "x": 108.0, "y": 121.78 }, "uuid": "55162730-46fd-465d-a1c5-20aed09ed534" }, { "description": "Durchsteckpad 8 [/RS_RTS] von U2", "pos": { "x": 160.78, "y": 130.0 }, "uuid": "5c304724-2bc6-409d-9c59-2e40adc557b9" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 9 [/RS_CTS] von U1", "pos": { "x": 108.0, "y": 124.32 }, "uuid": "f75c20f8-d3b5-4c3b-9919-cb044b2da5c3" }, { "description": "Durchsteckpad 9 [/RS_CTS] von U2", "pos": { "x": 163.32, "y": 130.0 }, "uuid": "a8411036-6859-4041-84b8-2c80c326c58e" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 10 [/RS_TX] von U1", "pos": { "x": 108.0, "y": 126.86 }, "uuid": "22c323db-7146-44af-951b-04a1d7dbb2fe" }, { "description": "Durchsteckpad 5 [/RS_TX] von U2", "pos": { "x": 153.16, "y": 130.0 }, "uuid": "f919098b-4ad7-4600-9e8b-3375a1cff050" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 11 [/RS_RX] von U1", "pos": { "x": 108.0, "y": 129.4 }, "uuid": "6573852d-5714-4c8d-8793-0be87f5a052a" }, { "description": "Durchsteckpad 4 [/RS_RX] von U2", "pos": { "x": 150.62, "y": 130.0 }, "uuid": "3d90cce4-14d8-46a0-b560-09524f11698f" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 12 [/RS_VALID] von U1", "pos": { "x": 108.0, "y": 131.94 }, "uuid": "2fbc596b-c88f-4fc6-aa94-5dad4fcac9cc" }, { "description": "Durchsteckpad 11 [/RS_VALID] von U2", "pos": { "x": 168.4, "y": 130.0 }, "uuid": "9ad42f44-160f-4aa5-bcf0-a4466c090438" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 15 [/RS_OFF_N] von U1", "pos": { "x": 108.0, "y": 139.56 }, "uuid": "34e1afe9-b3fc-4d3a-9e33-38b32244f19e" }, { "description": "Durchsteckpad 12 [/RS_OFF_N] von U2", "pos": { "x": 170.94, "y": 130.0 }, "uuid": "a43ba2f2-477d-4850-87de-e1591119d5ae" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/BTN_PREVIOUS] von SW1", "pos": { "x": 143.0, "y": 168.0 }, "uuid": "5214c011-545b-4ae7-9cdb-852ade815805" }, { "description": "Durchsteckpad 1 [/BTN_PREVIOUS] von SW1", "pos": { "x": 149.5, "y": 168.0 }, "uuid": "84202d30-b2fe-4170-8146-69b68d3b82a1" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/BTN_PREVIOUS] von SW1", "pos": { "x": 149.5, "y": 168.0 }, "uuid": "84202d30-b2fe-4170-8146-69b68d3b82a1" }, { "description": "Durchsteckpad 2 [/BTN_PREVIOUS] von R1", "pos": { "x": 150.62, "y": 134.0 }, "uuid": "8237f507-f5c7-4eb6-9aa1-f46af2981e7c" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 2 [/BTN_PREVIOUS] von R1", "pos": { "x": 150.62, "y": 134.0 }, "uuid": "8237f507-f5c7-4eb6-9aa1-f46af2981e7c" }, { "description": "Durchsteckpad 16 [/BTN_PREVIOUS] von U1", "pos": { "x": 108.0, "y": 142.1 }, "uuid": "fc705960-92fa-4d8f-bb0e-ce2b82d1e7fc" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 17 [/OLED_SDA] von U1", "pos": { "x": 108.0, "y": 144.64 }, "uuid": "1f91549c-5cb2-465f-86df-b2f1b0c16ed8" }, { "description": "Durchsteckpad 4 [/OLED_SDA] von DS1", "pos": { "x": 159.81, "y": 137.5 }, "uuid": "91a4dcef-1b36-4e3d-a15c-c4578077c27b" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 18 [/OLED_SCL] von U1", "pos": { "x": 108.0, "y": 147.18 }, "uuid": "1c55fd03-0b3e-494f-a37b-6e0b3496cfc9" }, { "description": "Durchsteckpad 3 [/OLED_SCL] von DS1", "pos": { "x": 157.27, "y": 137.5 }, "uuid": "704668d0-88bf-4b51-840a-60a35804fafd" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 20 [/BTN_NEXT] von U1", "pos": { "x": 108.0, "y": 152.26 }, "uuid": "e7159c90-4e8d-4b21-8e84-a7f59f793440" }, { "description": "Durchsteckpad 1 [/BTN_NEXT] von SW3", "pos": { "x": 167.0, "y": 168.0 }, "uuid": "c67d0b07-c47f-48b3-9e79-7aed82edbbfc" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/BTN_NEXT] von SW3", "pos": { "x": 167.0, "y": 168.0 }, "uuid": "c67d0b07-c47f-48b3-9e79-7aed82edbbfc" }, { "description": "Durchsteckpad 1 [/BTN_NEXT] von SW3", "pos": { "x": 173.5, "y": 168.0 }, "uuid": "62f3da3b-8297-4232-92ee-88f3ce4a7d36" } ], "severity": "error", "type": "unconnected_items" }, { "description": "Missing connection between items", "items": [ { "description": "Durchsteckpad 1 [/BTN_NEXT] von SW3", "pos": { "x": 173.5, "y": 168.0 }, "uuid": "62f3da3b-8297-4232-92ee-88f3ce4a7d36" }, { "description": "Durchsteckpad 2 [/BTN_NEXT] von R3", "pos": { "x": 172.62, "y": 134.0 }, "uuid": "9e9dfe49-4b68-472b-a86c-bfcee913a81b" } ], "severity": "error", "type": "unconnected_items" } ], "violations": [] }