@@ -4,7 +4,7 @@ These manual procedures verify the OLED and buttons, MAX3243 breakout, UART1 dat
> **Safety:** With power removed, install only the wiring required by the selected test. DE-9 pins 3 (`TX`), 4 (`DTR`), and 7 (`RTS`) are driven outputs. Never connect one of these outputs to another driven output. Keep temporary Dupont wiring short and secure. Power the OLED only from 3.3 V because module-mounted I²C pull-ups may connect SDA and SCL to the OLED `VCC` rail.
## Phase 7 OLED and button bring-up
## OLED and button checks
Use the exact OLED and button connections in [Hardware wiring](wiring.md). Display diagnostics initially operate I²C at 100 kHz and probe the standard 7-bit `0x3c` and `0x3d` addresses. The connected test module acknowledges at `0x3c`, whose 8-bit write/read forms are `0x78` and `0x79`. A missing or unresponsive display is nonfatal: diagnostics should report it without disrupting UART0 or the serial services.
@@ -31,7 +31,7 @@ If the expected address does not respond, treat the result as a nonfatal hardwar
### 3. Initialization and display patterns
Initialize the address observed during the scan. The tested module uses 7-bit `0x3c`, equivalently 8-bit `0x78` (write) and `0x79` (read):
Initialize the supported address found by the probe: `0x3c` or `0x3d`. An unexpected scan address is a finding to investigate, not an address accepted by `debug display init`. The tested module uses 7-bit `0x3c`, equivalently 8-bit `0x78` (write) and `0x79` (read):
```text
debug display init 0x3c
@@ -51,7 +51,7 @@ Confirm that clear and fill affect the full 128×64 area, checker and grid have
### 4. Rendered status/content layout
Run the Phase 7B panel-layout pattern:
Run the panel-layout pattern:
```text
debug display pattern layout
@@ -75,7 +75,7 @@ debug display pattern clear
debug display row 16
```
**Verified result:** row 15 is the last yellow addressable row and row 16 is the first blue addressable row. The two colored areas are separated by a narrow physical black divider, so later UI rendering must treat the 128×16 yellow and 128×48 blue regions as separate panels rather than one visually continuous canvas. Also test another endpoint row if needed with `debug display row <0..63>` to confirm row addressing and orientation.
On the tested two-color module, row 15 is the last yellow addressable row and row 16 is the first blue addressable row. The two colored areas are separated by a narrow physical black divider. Confirm that your module matches this layout: the UI uses separate 128×16 yellow and 128×48 blue panels. Also test another endpoint row if needed with `debug display row <0..63>` to confirm row addressing and orientation.
### 6. Contrast, inversion, and display-off checks
@@ -133,7 +133,7 @@ Confirm that each page remains entirely within the blue content panel. The yello
The UI refreshes at 4 Hz maximum. Status pages are observational and must not expose passwords, credentials, tickets, or key material. A short Select press opens the separate Controls menu described below; merely navigating status pages must not change a service, alter writer ownership, or inject serial data. With UART0, USB CDC, WebSocket, and SSH active, navigate pages and confirm that the display continues to update without disrupting serial traffic or UART0 recovery.
For the OLED-aging policy, leave all three buttons untouched and verify:
With the default dim/off settings (check `display status`), leave all three buttons untouched and verify:
1. At five minutes, display contrast drops to `1` while the contents remain present.
2. At ten minutes, the OLED switches off.
@@ -142,7 +142,7 @@ For the OLED-aging policy, leave all three buttons untouched and verify:
`debug display status` may verify an individual transition in a separate timing run. Every display diagnostic counts as activity and holds normal UI rendering for 30 seconds, so do not invoke it between the five- and ten-minute observations of one continuous run. Record any missing, stale, clipped, or implausible status value or incorrect dim/off/wake transition.
### 9. Local controls (Phase 7D)
### 9. Local controls
From a status page, use a short Select press to open **Controls**. Previous/next selects an item; Select activates it. The menu includes serial start/stop, Wi-Fi start/stop/reconnect/next-profile, HTTPS start/stop, SSH start/stop, writer revocation, display off, and reboot. `WiFi:next profile` requests the enabled station profile after the active one in priority order and wraps safely; it must never show or change credentials, Wi-Fi profile configuration, serial framing, TLS/SSH keys, or I²C scan controls.
@@ -159,11 +159,13 @@ For Wi-Fi lifecycle calls, confirm the immediate result says `Requested`, then u
Run these checks with UART0 available. Repeat appropriate stop/revoke cases with USB CDC, WebSocket, and SSH clients connected; verify the intended session/service is interrupted, unrelated recovery paths remain responsive, and no action injects serial data.
### 10. Phase 7E boot animation, persistence, and fault recovery
### 10. Boot animation, persistence, and fault recovery
On each normal boot with an initialized OLED, first verify the bounded five-second identity animation: the full `ESP32 SERIAL SWISS ARMY KNIFE` name scrolls across the yellow panel; the blue panel shows the compact right-oriented monochrome logo with an upright `>_` prompt and serial/USB cable ends entering from the left. Wi-Fi activity and the cursor blink at the 4 Hz animation cadence. A missing OLED must skip the animation without preventing normal UART0 recovery.
Then shorten the delays for a bounded aging-policy test:
Record your current `display status` settings before this test: it changes saved dim/off delays and finishes by saving defaults. Restore and save your preferred values afterward if needed.
Shorten the delays for a bounded dim/off test:
```text
display status
@@ -175,7 +177,7 @@ reboot
After reboot, `display status` must report the stored 5/10-second values. Verify dim at five seconds, off at ten seconds, and one consumed wake press. Run `display load`, then test `display defaults` without saving and confirm 300/600 seconds are restored only in RAM. Run `display reset`, reboot, and confirm the defaults persisted. Verify invalid combinations such as dim `10` with off `5` are rejected without changing the working values. Set either timeout to `0`, save/reboot, and confirm that transition is disabled; finish with `display reset`.
Exercise the following fault matrix while keeping UART0 available:
Exercise the following fault checks while keeping UART0 available. Button-triggered display recovery requires a running local UI task and an initialized I²C bus. If `debug display status` reports `bus=unavailable`, correct the wiring with power off and reboot; a button press cannot recreate the bus.
| Fault/stress | Procedure | Required result |
|---|---|---|
@@ -186,7 +188,11 @@ Exercise the following fault matrix while keeping UART0 available:
| Real chord | Press two healthy buttons together before either is quarantined. | The chord is ignored and cannot confirm an action. |
| Repeated actions | Re-enter Controls and repeat start/stop, reconnect, next-profile, writer-revoke, and display-off requests during transitions. | Each confirmation hold executes once; stale state produces an error rather than the opposite action; queue saturation, if reached, reports an error and leaves the Wi-Fi alert/counter visible. |
For the final concurrency regression, connect USB CDC, one WebSocket terminal, and one SSH terminal while UART1 carries sustained bidirectional traffic. Navigate the UI, run the persistence checks, exercise service stop/start and writer revocation, and inject the display/stuck-button faults above. Confirm UART0 remains responsive, the UI never appears as a broker client or injects serial bytes, writer ownership is always the expected client or none, and serial/broker drop counters do not increase unexpectedly. Record `memory`, transport counters, `wifi counters`, and `debug display status` before and after the run.
For a concurrent-transport check, connect USB CDC, one WebSocket terminal, and one SSH terminal while UART1 carries sustained bidirectional traffic. Navigate the UI, run the persistence checks, exercise service stop/start and writer revocation, and inject the display/stuck-button faults above. Confirm UART0 remains responsive, the UI never appears as a broker client or injects serial bytes, writer ownership is always the expected client or none, and serial/broker drop counters do not increase unexpectedly. Record `memory`, transport counters, `wifi counters`, and `debug display status` before and after the run.
## Before RS-232 diagnostics
Disconnect external DE-9 equipment and use UART0 for these checks. After each power-up, run `serial stop` before any RS-232 `debug` command, including `debug status`. The diagnostics refuse access while the serial service owns the port. If cleanup reports a port fault or a UART driver that could not be removed, reboot before continuing.
## Configuration A: data and handshake pairs