esphome:
name: sleepingroom
platform: ESP32
board: nodemcu-32s
# Dirty hack, because on_value_range does not trigger green if sensor
# value is within green range on boot.
on_boot:
then:
- output.set_level:
id: led_green
level: 58%
- output.set_level:
id: led_red
level: 0%
- text_sensor.template.publish:
id: co2_warn
state: "grün"
wifi:
ssid: "Voltage-legacy"
password: !secret voltage_legacy_psk
use_address: sleepingroom.home
power_save_mode: high
fast_connect: on
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Schlafzimmer Fallback Hotspot"
password: !secret fallback_psk
captive_portal:
# Enable logging
logger:
# Enable Home Assistant API
api:
password: !secret api
# Enable over-the-air updates
ota:
password: !secret ota
# Initialize I²C
i2c:
- id: bus_a
sda: 13
scl: 16
scan: true
# Initialize LEDC GPIOs
output:
- platform: ledc
pin: GPIO17
id: led_red
- platform: ledc
pin: GPIO18
id: led_green
# Create text sensor to represent CO2 LED warn state (somewhat redundant)
text_sensor:
- platform: template
name: "Schlafzimmer CO2 Warnstufe"
id: co2_warn
sensor:
# WiFi signal strength
- platform: wifi_signal
name: "WiFi Signalstärke"
update_interval: 60s
# SCD30 CO2 + Temperature + Humidity Sensor
# • Luftqualität Kategorie 1: die LEDs leuchten grün (bis 800 ppm)
# • Luftqualität Kategorie 2: die LEDs leuchten gelb (900-1200 ppm)
# • Luftqualität Kategorie 3: die LEDs leuchten orange (1200 bis 1600ppm)
# • Luftqualität Kategorie 4: die LEDs leuchten rot (ab 1600ppm)
- platform: scd30
i2c_id: bus_a
co2:
name: "Schlafzimmer CO2"
id: co2_value
accuracy_decimals: 1
on_value_range:
- above: 380
below: 800
then:
- output.set_level:
id: led_green
level: 58%
- output.set_level:
id: led_red
level: 0%
- text_sensor.template.publish:
id: co2_warn
state: "grün"
- above: 800
below: 1200
then:
- output.set_level:
id: led_green
level: 58%
- output.set_level:
id: led_red
level: 80%
- text_sensor.template.publish:
id: co2_warn
state: "gelb"
- above: 1200
below: 1600
then:
- output.set_level:
id: led_green
level: 50%
- output.set_level:
id: led_red
level: 100%
- text_sensor.template.publish:
id: co2_warn
state: "orange"
- above: 1600
then:
- output.set_level:
id: led_green
level: 0%
- output.set_level:
id: led_red
level: 100%
- text_sensor.template.publish:
id: co2_warn
state: "rot"
temperature:
name: "Schlafzimmer Temperatur"
accuracy_decimals: 2
humidity:
name: "Schlafzimmer Luftfeuchtigkeit"
accuracy_decimals: 1
# SCD30 temp sensor is a bit off
temperature_offset: 1.5 °C
ambient_pressure_compensation: 1
automatic_self_calibration: True
address: 0x61
update_interval: 60s
- platform: bmp280
i2c_id: bus_a
temperature:
name: "Schlafzimmer Temperatur alt"
oversampling: 16x
pressure:
name: "Schlafzimmer Luftdruck"
address: 0x76
update_interval: 60s
script:
- id: startup_animation
then:
- delay: 5s
-