Document Core2 BLE proxy power and UI logic

This commit is contained in:
2026-06-23 10:06:08 +02:00
parent cecec14be1
commit b22c86e95b
2 changed files with 141 additions and 18 deletions
+80 -17
View File
@@ -25,12 +25,16 @@ namespace owon_b35t {
using esphome::Color;
using esphome::display::Display;
// Log tags used by ESPHome for BLE meter parsing and Core2 power-management messages.
static const char *const TAG = "owon_b35t";
static const char *const POWER_TAG = "core2_power";
// The M5Stack Core2 routes LCD/backlight power through an AXP192 PMIC on I2C.
static constexpr uint8_t AXP192_ADDR = 0x34;
static esphome::i2c::I2CDevice axp192;
static bool axp192_ready = false;
static bool axp192_ready = false; // Guard PMIC accesses until the I2C bus/address has been configured.
// Write one byte to an AXP192 register and log failures instead of silently losing power changes.
static bool axp_write(uint8_t reg, uint8_t value) {
if (!axp192_ready) return false;
bool ok = axp192.write_byte(reg, value);
@@ -38,6 +42,7 @@ static bool axp_write(uint8_t reg, uint8_t value) {
return ok;
}
// Read one byte from an AXP192 register; callers use this before read/modify/write updates.
static bool axp_read(uint8_t reg, uint8_t *value) {
if (!axp192_ready) return false;
bool ok = axp192.read_byte(reg, value);
@@ -45,6 +50,7 @@ static bool axp_read(uint8_t reg, uint8_t *value) {
return ok;
}
// Clear and set selected bits in an AXP192 register while preserving all other bits.
static void axp_update(uint8_t reg, uint8_t clear_mask, uint8_t set_mask) {
uint8_t value = 0;
if (!axp_read(reg, &value)) return;
@@ -52,24 +58,28 @@ static void axp_update(uint8_t reg, uint8_t clear_mask, uint8_t set_mask) {
axp_write(reg, value);
}
// Convert a desired DCDC output voltage to the 25 mV-step register encoding used by AXP192.
static uint8_t axp_dc_voltage_data(uint16_t millivolts) {
if (millivolts < 700) millivolts = 700;
if (millivolts > 3500) millivolts = 3500;
return static_cast<uint8_t>((millivolts - 700) / 25) & 0x7F;
}
// Convert a desired LDO voltage to the 100 mV-step register encoding used by AXP192.
static uint8_t axp_ldo_voltage_data(uint16_t millivolts) {
if (millivolts < 1800) millivolts = 1800;
if (millivolts > 3300) millivolts = 3300;
return static_cast<uint8_t>((millivolts - 1800) / 100) & 0x0F;
}
// Set the LCD backlight rail (DCDC3) voltage; brightness is controlled by this rail voltage.
static void core2_axp192_set_lcd_voltage(uint16_t millivolts) {
uint8_t value = 0;
axp_read(0x27, &value);
axp_write(0x27, (value & 0x80) | axp_dc_voltage_data(millivolts)); // DCDC3, LCD backlight
}
// Map a 0.0-1.0 brightness value to the Core2 LCD backlight voltage and enable/disable DCDC3.
static void core2_axp192_set_backlight(float brightness) {
if (brightness <= 0.0f) {
axp_update(0x12, 0x02, 0x00); // DCDC3 off
@@ -81,6 +91,7 @@ static void core2_axp192_set_backlight(float brightness) {
axp_update(0x12, 0x00, 0x02); // DCDC3 on
}
// Initialize the Core2 PMIC rails needed by ESP32, LCD logic, LCD backlight, and the display reset line.
static void core2_axp192_init(esphome::i2c::I2CBus *bus) {
axp192.set_i2c_bus(bus);
axp192.set_i2c_address(AXP192_ADDR);
@@ -113,6 +124,7 @@ static void core2_axp192_init(esphome::i2c::I2CBus *bus) {
core2_axp192_set_backlight(1.0f);
}
// 16x16 monochrome status icons drawn manually into the ESPHome display framebuffer.
static const uint8_t ACCU_BMP[32] = {
0b00000000, 0b00000000,
0b00000000, 0b00000000,
@@ -229,6 +241,8 @@ static const uint8_t BUZZ_BMP[32] = {
class Meter {
public:
// Offsets and bit masks for the 14-byte "classic" OWON frame layout. B35T+ frames are
// normalized into this same buffer so the rest of the code can use one representation.
static constexpr uint8_t REGPLUSMINUS = 0x00;
static constexpr uint8_t FLAGPLUS = 0b00101011;
static constexpr uint8_t FLAGMINUS = 0b00101101;
@@ -268,24 +282,29 @@ class Meter {
static constexpr uint8_t FLAGUNITAMP = 0b01000000;
static constexpr uint8_t FLAGUNITVOLT = 0b10000000;
bool connected{false};
bool write_available{false};
bool is_plus{false};
bool low_battery{false};
bool overload{false};
bool has_reading{false};
uint8_t selected_button{1};
uint32_t last_notify_ms{0};
// Connection and decoded meter state consumed by ESPHome sensors and the local display.
bool connected{false}; // BLE link to the OWON meter is currently established.
bool write_available{false}; // The writable BLE characteristic is ready for button commands.
bool is_plus{false}; // True when the last notification used the compact B35T+ frame format.
bool low_battery{false}; // Battery indicator decoded from the meter status bits.
bool overload{false}; // True when the meter reports OL instead of numeric digits.
bool has_reading{false}; // At least one valid BLE notification has been decoded.
uint8_t selected_button{1}; // UI-selected OWON remote button command (1..6).
uint32_t last_notify_ms{0}; // Timestamp of the last accepted meter notification.
// Decode a BLE notification from either supported OWON protocol variant and refresh cached values.
bool handle_notify(const std::vector<uint8_t> &data) {
if (data.size() > sizeof(this->raw_))
return false;
// B35T+ sends a compact 6-byte binary frame; convert it into the classic 14-byte layout.
if (data.size() == 6 && data[1] >= 0xF0) {
memset(this->raw_, 0, sizeof(this->raw_));
memcpy(this->raw_, data.data(), data.size());
this->is_plus = true;
this->parse_plus_();
} else if (data.size() == 14 && data[12] == 0x0D && data[13] == 0x0A) {
// Classic B35T sends an ASCII-like 14-byte frame terminated by CR/LF; it can be used directly.
memset(this->value_, 0, sizeof(this->value_));
memcpy(this->value_, data.data(), data.size());
this->is_plus = false;
@@ -294,26 +313,32 @@ class Meter {
return false;
}
// Cache derived states so display drawing and Home Assistant sensors do not have to re-parse frames.
this->overload = memcmp(this->value_, OVERLOAD_FRAME, sizeof(OVERLOAD_FRAME)) == 0;
this->display_value = this->calc_display_value_();
this->base_value = this->calc_base_value_();
this->display_value = this->calc_display_value_(); // Numeric value exactly as shown on the meter.
this->base_value = this->calc_base_value_(); // Same reading converted to base SI scale.
this->has_reading = true;
this->last_notify_ms = millis();
return true;
}
// Called by the ESPHome BLE client once the meter connection and write characteristic are usable.
void on_connect() {
this->connected = true;
this->write_available = true;
}
// Reset connection flags when BLE disconnects; the last reading is kept for display/sensor continuity.
void on_disconnect() {
this->connected = false;
this->write_available = false;
}
// Numeric accessors used by ESPHome lambdas when publishing sensor state to Home Assistant.
float value() const { return this->display_value; }
float value_base() const { return this->base_value; }
// Boolean flag helpers keep the bit-mask details out of UI and sensor publishing code.
bool negative() const { return (this->value_[REGPLUSMINUS] & FLAGMINUS) == FLAGMINUS; }
bool auto_range() const { return (this->value_[REGMODE] & FLAGMODEAUTO) == FLAGMODEAUTO; }
bool hold() const { return (this->value_[REGMODE] & FLAGMODEHOLD) == FLAGMODEHOLD; }
@@ -325,6 +350,7 @@ class Meter {
bool diode() const { return (this->value_[REGSCALE] & FLAGSCALEDIODE) == FLAGSCALEDIODE; }
bool continuity() const { return (this->value_[REGSCALE] & FLAGSCALEBUZZ) == FLAGSCALEBUZZ; }
// Translate decoded unit bits into the text suffix shown on the display and exposed via sensors.
const char *unit() const {
switch (this->value_[REGUNIT]) {
case FLAGUNITFAHR: return "°F";
@@ -339,6 +365,7 @@ class Meter {
}
}
// Translate decoded scale bits into SI prefixes or duty-cycle percent.
const char *scale() const {
if ((this->value_[REGSCALE] & FLAGSCALEDUTY) == FLAGSCALEDUTY) return "%";
if ((this->value_[REGSCALE] & FLAGSCALEMEGA) == FLAGSCALEMEGA) return "M";
@@ -348,6 +375,7 @@ class Meter {
return "";
}
// Build a compact human-readable list of active meter modes for Home Assistant text sensors.
std::string mode_text() const {
std::string out;
if (this->dc()) out += "DC ";
@@ -363,6 +391,7 @@ class Meter {
return out;
}
// Format the current reading as a single string, including disconnected/waiting/overload states.
std::string reading_text() const {
if (!this->connected) return "Disconnected";
if (!this->has_reading) return "Waiting for data";
@@ -372,6 +401,7 @@ class Meter {
return std::string(buf);
}
// Classify the reading so ESPHome can publish it to the correct measurement-specific sensor.
enum Kind { KIND_OTHER, KIND_VOLTAGE, KIND_CURRENT, KIND_RESISTANCE, KIND_FREQUENCY, KIND_CAPACITANCE, KIND_TEMP_C, KIND_TEMP_F, KIND_DUTY };
Kind kind() const {
if ((this->value_[REGSCALE] & FLAGSCALEDUTY) == FLAGSCALEDUTY) return KIND_DUTY;
@@ -387,6 +417,7 @@ class Meter {
}
}
// UI label for the currently selected remote-control command sent back to the OWON meter.
const char *selected_button_name() const {
static const char *const names[] = {"SELECT", "RANGE", "HLD/LIG", "REL/BT", "HZ/DUTY", "MAX/MIN"};
uint8_t index = this->selected_button;
@@ -395,6 +426,7 @@ class Meter {
return names[index - 1];
}
// Move the selected remote button left/right; bounds match the six commands in selected_button_name().
void previous_button() {
if (this->selected_button > 1) this->selected_button--;
}
@@ -402,6 +434,7 @@ class Meter {
if (this->selected_button < 6) this->selected_button++;
}
// Draw either the OWON multimeter page or the Atorch DL24 load page on the M5Stack display.
void render(esphome::display::Display &it, esphome::display::BaseFont *font,
esphome::display::BaseFont *value_font, int display_page = 0,
bool atorch_connected = false,
@@ -422,7 +455,9 @@ class Meter {
if (display_page == 0) {
// --- PAGE 1: OWON Multimeter ---
it.fill(bg);
bool status_active = this->connected && this->has_reading;
bool status_active = this->connected && this->has_reading; // Only highlight decoded flags after data arrives.
// Top status row mirrors the physical meter annunciators: battery, BLE, range, min/max, hold, rel, diode, buzzer.
this->draw_icon_(it, 12, 8, 16, 16, ACCU_BMP, status_active ? (this->low_battery ? red : green) : inactive);
this->draw_icon_(it, 46, 8, 16, 16, BLE_BMP, this->connected ? blue : inactive);
this->label_(it, font, 86, 8, "AUTO", status_active && this->auto_range() ? fg : inactive);
@@ -436,6 +471,7 @@ class Meter {
this->label_(it, font, 8, 104, "DC", status_active && this->dc() ? cyan : inactive);
this->label_(it, font, 8, 124, "AC", status_active && this->ac() ? magenta : inactive);
// Main seven-segment area distinguishes connection, waiting-for-first-frame, overload, and normal readings.
if (!this->connected) {
this->draw_digits_(it, "----", false, inactive);
it.print(160, 148, font, inactive, esphome::display::TextAlign::CENTER, "scan/connect");
@@ -462,6 +498,8 @@ class Meter {
bool bargraph_active = status_active && !this->overload;
this->draw_bargraph_(it, bargraph_active ? this->digits_from_buffer_() : 0, bargraph_active);
// Bottom soft-button row shows the currently selected OWON command and whether BLE writes are available.
it.filled_rectangle(34, 212, 40, 24, this->write_available ? fg : inactive);
it.filled_rectangle(108, 212, 100, 24, this->write_available ? fg : inactive);
it.filled_rectangle(242, 212, 40, 24, this->write_available ? fg : inactive);
@@ -488,6 +526,7 @@ class Meter {
const Color temp_color = atorch_connected ? magenta : dim_accent;
const Color header_color = atorch_connected ? cyan : dim_value;
// Prepare formatted metric strings before drawing so missing/NaN Atorch values display consistently.
char voltage_text[24];
char current_text[24];
char power_text[24];
@@ -508,6 +547,7 @@ class Meter {
}
it.print(310, 7, font, inactive, esphome::display::TextAlign::TOP_RIGHT, "DC LOAD");
// Four primary Atorch measurements are shown as dashboard cards; accumulated counters fit in the footer.
this->draw_metric_card_(it, font, value_font, 10, 42, 145, 76, "VOLTAGE", voltage_text, voltage_color, panel, border, value_color);
this->draw_metric_card_(it, font, value_font, 165, 42, 145, 76, "CURRENT", current_text, current_color, panel, border, value_color);
this->draw_metric_card_(it, font, value_font, 10, 128, 145, 76, "POWER", power_text, power_color, panel, border, value_color);
@@ -526,12 +566,13 @@ class Meter {
}
private:
uint8_t raw_[14]{};
uint8_t value_[14]{};
float display_value{NAN};
float base_value{NAN};
static constexpr uint8_t OVERLOAD_FRAME[5] = {0x2B, 0x3F, 0x30, 0x3A, 0x3F};
uint8_t raw_[14]{}; // Last raw BLE payload, padded to the maximum supported OWON frame length.
uint8_t value_[14]{}; // Normalized classic-frame view used by all accessors and display rendering.
float display_value{NAN}; // Meter reading with its displayed prefix still applied, e.g. 12.3 kΩ -> 12.3.
float base_value{NAN}; // Meter reading converted to base units, e.g. 12.3 kΩ -> 12300 Ω.
static constexpr uint8_t OVERLOAD_FRAME[5] = {0x2B, 0x3F, 0x30, 0x3A, 0x3F}; // "+?0:?" OL marker.
// Reconstruct the four visible seven-segment digits as an integer for value calculations/bargraph scaling.
uint16_t digits_from_buffer_() const {
uint16_t out = 0;
if (this->value_[REGDIG1] >= '0' && this->value_[REGDIG1] <= '9') out += (this->value_[REGDIG1] - '0') * 1000;
@@ -541,10 +582,12 @@ class Meter {
return out;
}
// Convert the normalized frame into the floating-point number shown by the meter display.
float calc_display_value_() const {
if (this->overload) return NAN;
if (this->is_plus) {
// B35T+ encodes decimal placement and sign/magnitude as packed little-endian words.
uint16_t pair1 = static_cast<uint16_t>(this->raw_[0]) | (static_cast<uint16_t>(this->raw_[1]) << 8);
uint8_t decimal = pair1 & 0x07;
if (decimal >= 7) return NAN;
@@ -556,6 +599,7 @@ class Meter {
return negative ? -v : v;
}
// Classic frames carry decimal placement as one of three point flags in the normalized buffer.
uint8_t decimal = 0;
switch (this->value_[REGPOINT] & 0x07) {
case 0b001: decimal = 1; break;
@@ -567,6 +611,7 @@ class Meter {
return this->negative() ? -v : v;
}
// Apply the decoded SI prefix so Home Assistant receives comparable base-unit sensor values.
float calc_base_value_() const {
if (std::isnan(this->display_value)) return NAN;
if (this->value_[REGUNIT] == FLAGUNITNF) return this->display_value * 1e-9f;
@@ -577,17 +622,20 @@ class Meter {
return this->display_value;
}
// Decode the compact B35T+ payload and synthesize the 14-byte classic representation.
void parse_plus_() {
memset(this->value_, 0, sizeof(this->value_));
this->value_[5] = 0x20;
this->value_[12] = 0x0D;
this->value_[13] = 0x0A;
// First word: measurement function, SI scale, and decimal-point position.
uint16_t pair1 = static_cast<uint16_t>(this->raw_[0]) | (static_cast<uint16_t>(this->raw_[1]) << 8);
uint8_t function = (pair1 >> 6) & 0x0F;
uint8_t scale = (pair1 >> 3) & 0x07;
uint8_t decimal = pair1 & 0x07;
// Translate B35T+ decimal count to the classic point-flag convention used by draw_decimal_points_().
switch (decimal) {
case 0: this->value_[REGPOINT] = FLAGPOINT0; break;
case 1: this->value_[REGPOINT] = FLAGPOINT3; break;
@@ -596,6 +644,7 @@ class Meter {
default: break;
}
// Translate the function selector into classic unit and AC/DC/mode flags.
switch (function) {
case 0: this->value_[REGUNIT] |= FLAGUNITVOLT; this->value_[REGMODE] |= FLAGMODEDC; break;
case 1: this->value_[REGUNIT] |= FLAGUNITVOLT; this->value_[REGMODE] |= FLAGMODEAC; break;
@@ -613,6 +662,7 @@ class Meter {
default: break;
}
// Translate the B35T+ scale selector into SI-prefix flags.
switch (scale) {
case 2: this->value_[REGSCALE] |= FLAGSCALEMICRO; break;
case 3: this->value_[REGSCALE] |= FLAGSCALEMILLI; break;
@@ -621,6 +671,7 @@ class Meter {
default: break;
}
// Second word: status flags such as hold, relative, auto-range, battery, and min/max.
uint16_t pair2 = static_cast<uint16_t>(this->raw_[2]) | (static_cast<uint16_t>(this->raw_[3]) << 8);
if (pair2 & (1 << 0)) this->value_[REGMODE] |= FLAGMODEHOLD;
if (pair2 & (1 << 1)) this->value_[REGMODE] |= FLAGMODEREL;
@@ -629,6 +680,7 @@ class Meter {
if (pair2 & (1 << 4)) this->value_[REGMINMAX] |= FLAGMIN;
if (pair2 & (1 << 5)) this->value_[REGMINMAX] |= FLAGMAX;
// Third word: signed 4-digit display value, with bit 15 indicating a negative reading.
uint16_t pair3 = static_cast<uint16_t>(this->raw_[4]) | (static_cast<uint16_t>(this->raw_[5]) << 8);
if (decimal < 7) {
uint16_t digits = pair3;
@@ -643,15 +695,18 @@ class Meter {
this->value_[REGDIG3] = '0' + ((digits / 10) % 10);
this->value_[REGDIG4] = '0' + (digits % 10);
} else {
// Decimal values 7 and above are used by this protocol to indicate overload/OL.
memcpy(this->value_, OVERLOAD_FRAME, sizeof(OVERLOAD_FRAME));
}
}
// Return a printable digit for a display register, using a blank for non-digit status bytes.
char digit_char_(uint8_t reg) const {
uint8_t c = this->value_[reg];
return (c >= '0' && c <= '9') ? static_cast<char>(c) : ' ';
}
// Format Atorch metrics, using "--" for missing values while keeping units visible.
void format_metric_(char *buffer, size_t size, float value, const char *unit, uint8_t decimals) const {
if (!std::isfinite(value)) {
snprintf(buffer, size, "-- %s", unit);
@@ -662,6 +717,7 @@ class Meter {
snprintf(buffer, size, format, value, unit);
}
// Draw one Atorch dashboard tile with a colored accent, label, and centered numeric value.
void draw_metric_card_(Display &it, esphome::display::BaseFont *label_font, esphome::display::BaseFont *value_font,
int x, int y, int w, int h, const char *title, const char *value,
Color accent, Color fill, Color border, Color value_color) {
@@ -678,10 +734,12 @@ class Meter {
it.filled_rectangle(x + 10, y + h - 11, w - 20, 1, accent);
}
// Small wrapper for consistent top-left aligned labels.
void label_(Display &it, esphome::display::BaseFont *font, int x, int y, const char *text, Color color) {
it.print(x, y, font, color, esphome::display::TextAlign::TOP_LEFT, text);
}
// Draw the large four-digit OWON readout, including a separate minus sign when needed.
void draw_digits_(Display &it, const char *text, bool negative, Color color) {
if (negative) this->draw_segment_(it, 8, 83, 26, 9, true, color);
constexpr int digit_x = 40;
@@ -694,6 +752,7 @@ class Meter {
}
}
// Draw decimal points between the large seven-segment digits according to the normalized frame flags.
void draw_decimal_points_(Display &it, Color color) {
uint8_t p = this->value_[REGPOINT];
if ((p & FLAGPOINT1) == FLAGPOINT1) it.filled_rectangle(95, 135, 8, 10, color);
@@ -701,6 +760,7 @@ class Meter {
if ((p & FLAGPOINT3) == FLAGPOINT3) it.filled_rectangle(223, 135, 8, 10, color);
}
// Draw one beveled horizontal or vertical segment used by the custom seven-segment font.
void draw_segment_(Display &it, int x, int y, int w, int h, bool horizontal, Color color) {
if (horizontal) {
int cap = h / 2;
@@ -715,6 +775,7 @@ class Meter {
}
}
// Plot a packed 1-bit bitmap icon, where each set bit becomes one colored display pixel.
void draw_icon_(Display &it, int x, int y, int w, int h, const uint8_t *data, Color color) {
for (int row = 0; row < h; row++) {
for (int col = 0; col < w; col++) {
@@ -726,6 +787,7 @@ class Meter {
}
}
// Map a digit/OL/minus character to seven segment states and draw the active segments.
void draw_seven_segment_(Display &it, int x, int y, int w, int h, char ch, Color color) {
bool a=false,b=false,c=false,d=false,e=false,f=false,g=false;
switch (ch) {
@@ -766,6 +828,7 @@ class Meter {
if (g) this->draw_segment_(it, x + t / 2, mid_y, w - t, t, true, color);
}
// Draw the OWON-style bottom bargraph by scaling raw 0..6000 display digits to a 240 px ruler.
void draw_bargraph_(Display &it, uint16_t digits, bool active) {
const Color fg(255, 255, 255);
const Color inactive(80, 80, 80);
+61 -1
View File
@@ -29,6 +29,9 @@ esphome:
on_boot:
priority: 850
then:
# The Core2 LCD/backlight rails are controlled by the AXP192 PMIC. ESPHome's
# stock M5CORE2 display setup does not initialize those rails here, so the
# custom header performs the M5Stack-specific power sequencing once I2C exists.
- lambda: |-
owon_b35t::core2_axp192_init(id(core2_i2c));
project:
@@ -77,10 +80,14 @@ wifi:
captive_portal:
globals:
# 0 = OWON meter page, 1 = Atorch DL24 page. This is intentionally volatile so
# every boot starts with the multimeter view until one device connects.
- id: display_page
type: int
initial_value: "0"
restore_value: no
# The Atorch external component does not expose a simple connected flag that the
# display lambda can query, so BLE callbacks maintain this state explicitly.
- id: atorch_connected
type: bool
initial_value: "false"
@@ -100,15 +107,19 @@ script:
- delay: 2min
- if:
condition:
# Only dim when both BLE devices are disconnected; active lab instruments
# keep the display fully lit so readings remain visible at a glance.
lambda: |-
return !owon_meter.connected && !id(atorch_connected);
then:
- light.turn_on:
id: backlight
brightness: 50%
brightness: 70%
- delay: 3min
- if:
condition:
# Re-check before turning the backlight off, because a connection may
# have been established during the preceding delay.
lambda: |-
return !owon_meter.connected && !id(atorch_connected);
then:
@@ -117,6 +128,8 @@ script:
interval:
- interval: 10s
then:
# Periodic memory telemetry is useful on the Core2 because BLE, PSRAM, the
# MIPI framebuffer, and external components can fragment different heap pools.
- lambda: |-
ESP_LOGI("mem", "heap free=%u min_free=%u internal_free=%u internal_largest=%u dma_free=%u dma_largest=%u psram_free=%u psram_largest=%u",
static_cast<unsigned>(esp_get_free_heap_size()),
@@ -139,12 +152,16 @@ ble_client:
on_connect:
then:
- script.execute: wake_backlight
# Notify the custom parser/display object and switch to the meter page when
# the OWON connects, so the on-device screen follows the active instrument.
- lambda: |-
owon_meter.on_connect();
id(display_page) = 0;
id(lcd).update();
on_disconnect:
then:
# Keep the UI useful after a disconnect: if the Atorch is still online,
# automatically fall back from the OWON page to the Atorch page.
- lambda: |-
owon_meter.on_disconnect();
if (id(display_page) == 0 && id(atorch_connected)) {
@@ -153,6 +170,8 @@ ble_client:
id(lcd).update();
- if:
condition:
# Start the idle timer only after both BLE clients are gone; otherwise
# the remaining connected instrument still deserves an active display.
lambda: |-
return !owon_meter.connected && !id(atorch_connected);
then:
@@ -163,12 +182,16 @@ ble_client:
on_connect:
then:
- script.execute: wake_backlight
# The Atorch component handles measurements, while this explicit flag/page
# switch keeps the shared display state synchronized with the BLE client.
- lambda: |-
id(atorch_connected) = true;
id(display_page) = 1;
id(lcd).update();
on_disconnect:
then:
# If the load disconnects while the meter is still connected, move the
# physical display back to the meter instead of leaving a stale load page.
- lambda: |-
id(atorch_connected) = false;
if (id(display_page) == 1 && owon_meter.connected) {
@@ -177,6 +200,8 @@ ble_client:
id(lcd).update();
- if:
condition:
# Same idle rule as OWON disconnect: only dim/off when neither BLE
# target is connected anymore.
lambda: |-
return !owon_meter.connected && !id(atorch_connected);
then:
@@ -203,6 +228,8 @@ output:
type: float
id: lcd_backlight
write_action:
# Bridge ESPHome's generic monochromatic light level to the Core2-specific
# AXP192 backlight voltage helper implemented in lab-ble-proxy.h.
- lambda: |-
owon_b35t::core2_axp192_set_backlight(state);
@@ -217,6 +244,8 @@ font:
- file: "fonts/Roboto-Regular.ttf"
id: meter_font
size: 15
# Glyphs are whitelisted to save flash/RAM; include symbols used by units,
# status labels, soft-button names, and Atorch metric text.
glyphs:
[
" ",
@@ -293,6 +322,7 @@ font:
- file: "fonts/Roboto-Medium.ttf"
id: atorch_value_font
size: 22
# Larger Atorch value font only needs numeric characters and measurement units.
glyphs:
[
" ",
@@ -322,6 +352,8 @@ display:
id: lcd
model: M5CORE2
update_interval: 500ms
# Rendering is delegated to the custom C++ helper because ESPHome display YAML
# primitives would be unwieldy for the OWON seven-segment clone and Atorch dashboard.
lambda: |-
owon_meter.render(
it,
@@ -346,6 +378,8 @@ touchscreen:
- script.execute: wake_backlight
- if:
condition:
# Touching an idle/disconnected unit wakes the display briefly, then
# restarts the idle timer if no BLE target is available.
lambda: |-
return !owon_meter.connected && !id(atorch_connected);
then:
@@ -361,6 +395,7 @@ binary_sensor:
y_max: 195
on_press:
then:
# The large middle touch zone toggles between the two custom render pages.
- lambda: |-
id(display_page) = 1 - id(display_page);
id(lcd).update();
@@ -374,6 +409,7 @@ binary_sensor:
internal: true
on_press:
then:
# Left soft button changes which OWON remote command the center button will send.
- lambda: |-
owon_meter.previous_button();
- platform: touchscreen
@@ -396,6 +432,8 @@ binary_sensor:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# OWON remote-control payload: first byte selects the meter button,
# second byte selects the normal/short-press action variant.
value: !lambda |-
std::vector<uint8_t> data = {owon_meter.selected_button, 0x01};
return data;
@@ -410,6 +448,8 @@ binary_sensor:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# Long-press encoding is not uniform: SELECT and HZ/DUTY still use
# 0x01, while RANGE/HOLD/REL/MAX-MIN use 0x00 for their alternate action.
value: !lambda |-
uint8_t press_type = (owon_meter.selected_button == 1 || owon_meter.selected_button == 5) ? 0x01 : 0x00;
std::vector<uint8_t> data = {owon_meter.selected_button, press_type};
@@ -424,12 +464,14 @@ binary_sensor:
internal: true
on_press:
then:
# Right soft button advances to the next OWON command label.
- lambda: |-
owon_meter.next_button();
- platform: template
name: "${friendly_name} OWON Connected"
icon: "mdi:bluetooth-connect"
# Template binary sensors expose state maintained by the custom OWON parser object.
lambda: |-
return owon_meter.connected;
- platform: template
@@ -450,6 +492,8 @@ binary_sensor:
return id(atorch_connected);
sensor:
# This hidden characteristic sensor is the bridge from OWON BLE notifications into
# custom C++ parsing. The returned float becomes the source numeric meter reading.
- platform: ble_client
type: characteristic
ble_client_id: owon_ble_client
@@ -488,6 +532,8 @@ sensor:
name: "${friendly_name} Atorch Dim Backlight"
id: atorch_dim_backlight
# The DL24 component exposes power, but this config computes Wh locally so the
# accumulated energy can be restored and reset alongside Atorch's own counters.
- platform: integration
name: "${friendly_name} Atorch Energy"
id: atorch_energy_calculated
@@ -506,18 +552,21 @@ text_sensor:
name: "${friendly_name} OWON Reading"
update_interval: 1s
icon: "mdi:gauge"
# Human-readable mirror of the meter LCD, including waiting/disconnected/OL states.
lambda: |-
return owon_meter.reading_text();
- platform: template
name: "${friendly_name} OWON Unit"
update_interval: 1s
icon: "mdi:ruler"
# Combines SI prefix and unit into one HA text entity, e.g. mV, kΩ, µA, %.
lambda: |-
return std::string(owon_meter.scale()) + owon_meter.unit();
- platform: template
name: "${friendly_name} OWON Mode"
icon: "mdi:knob"
update_interval: 1s
# Exposes decoded annunciators such as AC/DC, AUTO, HOLD, REL, MIN/MAX.
lambda: |-
return owon_meter.mode_text();
@@ -535,6 +584,7 @@ button:
reset_all:
name: "${friendly_name} Atorch Reset All"
on_press:
# Keep the locally integrated Wh counter in sync with the DL24 reset-all command.
- sensor.integration.reset: atorch_energy_calculated
usb_plus:
name: "${friendly_name} Atorch Plus"
@@ -544,6 +594,8 @@ button:
name: "${friendly_name} Atorch Setup"
enter:
name: "${friendly_name} Atorch Enter"
# Home Assistant button entities for direct OWON remote commands. The payloads
# are the same two-byte command format used by the touchscreen soft buttons.
- platform: template
name: "OWON SELECT"
id: owon_btn_select
@@ -552,6 +604,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# SELECT normal press.
value: !lambda "return std::vector<uint8_t>({1, 0x01});"
- platform: template
@@ -562,6 +615,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# RANGE normal press.
value: !lambda "return std::vector<uint8_t>({2, 0x01});"
- platform: template
@@ -572,6 +626,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# HOLD is the short/normal action on the shared HLD/LIG physical key.
value: !lambda "return std::vector<uint8_t>({3, 0x01});"
- platform: template
@@ -582,6 +637,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# LIGHT is the alternate/long action on the same HLD/LIG key.
value: !lambda "return std::vector<uint8_t>({3, 0x00});"
- platform: template
@@ -592,6 +648,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# RELATIVE is the short/normal action on the shared REL/BT key.
value: !lambda "return std::vector<uint8_t>({4, 0x01});"
- platform: template
@@ -602,6 +659,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# BT is the alternate/long action on the same REL/BT key.
value: !lambda "return std::vector<uint8_t>({4, 0x00});"
- platform: template
@@ -612,6 +670,7 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# HZ/DUTY command uses the normal action variant.
value: !lambda "return std::vector<uint8_t>({5, 0x01});"
- platform: template
@@ -622,4 +681,5 @@ button:
id: owon_ble_client
service_uuid: "0000fff0-0000-1000-8000-00805f9b34fb"
characteristic_uuid: "0000fff3-0000-1000-8000-00805f9b34fb"
# MAX/MIN command uses the normal action variant.
value: !lambda "return std::vector<uint8_t>({6, 0x01});"